NS SAVANNAH PRIMARY COOLANT PUMP REPLACEMENT. PART 2: PUMP REPLACEMENT AND TEST

As a result of failure of two of the N.S. Savannah's four rotor primary coolant pumps, all four primary system pumps were replaced. This report covers the replacement of the pumps. The modifications and installation work was complete and the reactor critical within 94 days.

  • Supplemental Notes:
    • This document is available for review at the Department of Commerce Library, Main Commerce Building, Washington, D.C., under reference number STS-72A.
  • Corporate Authors:

    Savannah Technical Staff

    Maritime Administration and Atomic Energy Commission
    Washington, DC  United States 
  • Publication Date: 1966-5

Media Info

  • Pagination: 3 p.

Subject/Index Terms

Filing Info

  • Accession Number: 00027586
  • Record Type: Publication
  • Source Agency: Maritime Administration
  • Report/Paper Numbers: STS-72A
  • Contract Numbers: NP-16299 (Pt 2)
  • Files: TRIS, USDOT