THE MORNING AFTER
In the event of an electrical storm, no single device can provide 100% protection for traffic signal controllers. The survival of traffic control equipment and its chances of continuing operation, without interruption or error, depends upon a series of protective measures. These include grounded 'static' wires run above the phase conductors and 'earthed' via wires on the poles connected to ground rods at the base, a very high quality multi-stage bidirectional filter network (series electronic filter), and a single point grounding system (zero reference point) for all of the interactive traffic control equipment's chassis grounds established in the cabinet.
-
Availability:
- Find a library where document is available. Order URL: http://worldcat.org/oclc/7529443
-
Corporate Authors:
International Municipal Signal Association
PO Box 539, 1115 North Main Street
Newark, NY United States 14513 -
Authors:
- Casey, T R
- Publication Date: 1988-10
Media Info
- Pagination: p. 12-13
-
Serial:
- IMSA Journal
- Volume: 25
- Issue Number: 5
- Publisher: International Municipal Signal Association
- ISSN: 10642560
- Serial URL: http://www.imsasafety.org
Subject/Index Terms
- TRT Terms: Lightning; Protection; Traffic signal controllers
- Subject Areas: Highways; Maintenance and Preservation; Operations and Traffic Management; Security and Emergencies; I73: Traffic Control;
Filing Info
- Accession Number: 00477108
- Record Type: Publication
- Files: TRIS
- Created Date: Nov 30 1988 12:00AM