CORROSION OF CABLE SUSPENSION BRIDGES. INTERIM REPORT
This report discusses corrosion problems encountered on the cables of suspension bridges. A historical review is given of past cable suspension bridge corrosion and related laboratory work. Findings of inspections of suspension bridges at Maysville, KY, Covington, KY, and Portsmouth, OH, are discussed. Recommendations are presented.
- Record URL:
-
Corporate Authors:
University of Kentucky, Lexington
Kentucky Transportation Center
College of Engineering, 176 Raymond Building
Lexington, KY United States 40506-0281Kentucky Transportation Cabinet
200 Mero Street
Frankfort, KY United States 40622Federal Highway Administration
1200 New Jersey Avenue, SE
Washington, DC United States 20590 -
Authors:
- Hopwood II, T
- Havens, J H
- Publication Date: 1984-5
Media Info
- Features: Appendices; Figures; Tables;
- Pagination: 70 p.
Subject/Index Terms
- TRT Terms: Cable stayed bridges; Corrosion; Inspection; Recommendations; Suspension bridges
- Subject Areas: Bridges and other structures; Design; Geotechnology; Highways; Maintenance and Preservation; Materials; Research; I24: Design of Bridges and Retaining Walls;
Filing Info
- Accession Number: 00453702
- Record Type: Publication
- Report/Paper Numbers: UKTRP-84-14
- Contract Numbers: KY-84-95
- Files: TRIS, USDOT, STATEDOT
- Created Date: Jul 31 1988 12:00AM