INPUT POWER CHARACTERISTICS OF A THREE-PHASE THYRISTOR CONVERTER
A phase delay rectifier operating into a passive resistive load was instrumented in the laboratory. Techniques for accurate measurement of power, displacement reactive power, harmonic components, and distortion reactive power are presented. The characteristics of the phase delay rectifier operating with unfiltered and inductively filtered resistive loads are presented using both derivations and measurements. The changes of the phase delay rectifier characteristics with a free wheeling diode in the circuit are also presented. /Author/
-
Corporate Authors:
Transportation Systems Center
55 Broadway, Kendall Square
Cambridge, MA United States 02142 -
Authors:
- Wlodyka, R A
- Abbas, J D
- Ploetz, G
- Publication Date: 1973-10
Media Info
- Pagination: 90 p.
Subject/Index Terms
- TRT Terms: Electrical impedance; Power converters; Rectifiers; Thyristors
- Old TRIS Terms: Converters; Load impedance
- Subject Areas: Materials; Railroads;
Filing Info
- Accession Number: 00071936
- Record Type: Publication
- Source Agency: Federal Railroad Administration
- Report/Paper Numbers: FRA-ORD/D-74-20 Final Rpt.
- Files: TRIS, USDOT
- Created Date: Dec 13 1974 12:00AM