A ROAD LIGHTING CODE BASED ON CIE PHILOSOPHY

A design table, derived for each road lighting luminaire, and two simple formulae are used to give the column spacing, overall and longitudinal uniformities, and threshold increment corresponding to a specified road luminance. Account is taken of lamp and luminaire depreciation. Column positioning on bends is arrived at by means of iso-luminance templates. (Author/TRRL)

  • Supplemental Notes:
    • This paper was presented at the 20th session of the CIE, International Commission on Illumination, held in Amsterdam, August 31-September 8, 1983, Volume 1, E29.
  • Corporate Authors:

    Bureau Cent de la commission Intl de l'Eclairage

    52 Boulevard Malsherbes
    Paris,   France 
  • Authors:
    • Hargroves, R A
    • Martin, N J
    • SIMONS, R H
    • Simpson, M D
  • Publication Date: 0

Media Info

Subject/Index Terms

Filing Info

  • Accession Number: 00385216
  • Record Type: Publication
  • Source Agency: Institute for Road Safety Research, SWOV
  • Files: ITRD, TRIS
  • Created Date: May 30 1984 12:00AM