CLASSIFICATION OF DEFECTS SEEN IN SURVEYS OF BRICK SEWERS BY CLOSED-CIRCUIT TELEVISION
The "Manual of Sewer Condition Classification" has been published as a training and operating manual for use both by operatives and by engineers. This report is intended as a supplement to the manual. It deals with brick sewer condition classification in more detail than was possible in the manual, discusses some changes that have proved desirable in the light of subsequent experience, and describes a number of difficulties that may be encountered in using the system on site. (Author/TRRL)
-
Availability:
- Find a library where document is available. Order URL: http://worldcat.org/issn/03051315
-
Corporate Authors:
Transport and Road Research Laboratory (TRRL)
Wokingham, Berkshire United Kingdom -
Authors:
- FARRAR, D M
- Rushbrooke, J N
- McCloskey, A
- Publication Date: 1983
Media Info
- Features: Photos; References; Tables;
- Pagination: 14 p.
-
Serial:
- Supplementary Report
- Issue Number: 800
- Publisher: Transport and Road Research Laboratory (TRRL)
- ISSN: 0305-1315
Subject/Index Terms
- TRT Terms: Brick; Classification; Closed circuit television; Defects; Drainage; Inspection; Manuals; Pipe; Sewers; Surveillance; Television
- ITRD Terms: 8513: Classification; 5238: Defect (tech); 2937: Drainage; 3361: Pipe; 9101: Surveillance; 6949: Television
- Subject Areas: Highways; Hydraulics and Hydrology; I26: Water Run-off - Freeze-thaw;
Filing Info
- Accession Number: 00382832
- Record Type: Publication
- Source Agency: Transport Research Laboratory
- Report/Paper Numbers: SR 789 Monograph
- Files: ITRD, TRIS, ATRI
- Created Date: May 30 1984 12:00AM