A COMPENSATION CONDUCTOR--AS AN ALTERNATIVE TO THE PROBLEMS OF ELECTRICAL INTERFERENCE
DER KOMPENSATIONSLEITER--EINE ALTERNATIVE ZUR LOESUNG ELEKTRISCHER BEEINFLUSSUNGSPROBLEME
In order to reduce interference caused by railway electrical equipment on nearby signalling and telecommunications cables, measures have been taken with regard to both vehicles and equipment to weaken harmonics. As power increases, the effects of fundamentals are correspondingly greater. To reduce the latter, it may be advisable to place a compensation cable near the catenary or near the cable suffering interference (the telecommunication line for instance). For economic reasons, it is often fitted on catenary masts.
-
Corporate Authors:
Verlag R Oldenbourg
Rosenheimer Strasse 145
Munich 80, Germany -
Authors:
- Bethge, W
- Dorendorf, K
- Publication Date: 1983-6
Language
- German
Media Info
- Features: Photos; References; Tables;
- Pagination: p. 188-196
-
Serial:
- Elektrische Bahnen
- Volume: 81
- Issue Number: 6
- Publisher: Verlag R Oldenbourg
Subject/Index Terms
- TRT Terms: Cables; Catenaries (Railroads); Electric power conditioning; Electromagnetic interference; Employee compensation; Railroad electrification; Signaling; Telecommunications
- Uncontrolled Terms: Compensation
- Subject Areas: Operations and Traffic Management; Public Transportation; Railroads;
Filing Info
- Accession Number: 00381534
- Record Type: Publication
- Source Agency: International Union of Railways
- Files: TRIS
- Created Date: Feb 29 1984 12:00AM