OPERATIONAL CHEMICAL CLEANING OF ONCE-THROUGH BOILERS BY A SIMPIFIED METHOD

To carry out a chemical clean by the simplified technique it is advisable to use a solution of disubstitution ammonium salt of EDTA at a concentration of 0.03-0.05%, a temperature scavenging solution of about 150 C and a velocity of 1.5-2 m/s. Under these conditions, cleaning the LRS of a PK-41 boiler in an open system takes 4-6 h. Putting the boiler back into operation immediately after clean enables separate passivation of the metal to be avoided; passivation takes place during the process of bringing the boiler up to working parameters.

  • Corporate Authors:

    Combustion Publication Company

    277 Park Avenue
    New York, NY  United States  10017
  • Authors:
    • Mamet, A P
    • Aleinikov, G I
    • Taratuta, V A
    • Peskov, V A
    • Drobot, G K
    • Marakov, N V
  • Publication Date: 1973-11

Media Info

  • Features: References;
  • Pagination: p. 21-24
  • Serial:
    • Combustion
    • Volume: 45
    • Issue Number: 5
    • Publisher: Combustion Publication Company

Subject/Index Terms

Filing Info

  • Accession Number: 00053961
  • Record Type: Publication
  • Source Agency: Engineering Index
  • Files: TRIS
  • Created Date: May 7 1974 12:00AM