A SIMPLE AXIAL DISPLACEMENT GAUGE FOR USE IN THE TRIAXIAL APPARATUS
The use of electrolytic liquid levels as horizontal inclinometers is described for the measurement of local displacements and strains on laboratory soil samples. The simplicity, accuracy and low-cost of electrolytic levels are said to make such units useful in transducer applications. The liquid level consists of an electrolyte sealed in a glass capsule with three co-planar electrodes partially immersed in the electrolyte. Resistance between the electrodes vary as the capsule is tilted. Inclinometer apparatus described uses an electrolevel for measurement of local torsional strains in soil and it is shown how such a vertical deflection gauge can be used in a triaxial test apparatus for application in routine soil testing. (Author/TRRL)
-
Availability:
- Find a library where document is available. Order URL: http://worldcat.org/issn/00168505
-
Corporate Authors:
Institution of Civil Engineers
One Great George Street, Westminster
London, United Kingdom SW1P 3AA -
Authors:
- Burland, J B
- Symes, M
- Publication Date: 1982-3
Media Info
- Features: Figures; Photos; References;
- Pagination: p. 62-65
-
Serial:
- GEOTECHNIQUE
- Volume: 32
- Issue Number: 1
- Publisher: Thomas Telford Limited
- ISSN: 0016-8505
Subject/Index Terms
- TRT Terms: Dislocation (Geology); Electrodes; Electrolytes; Measurement; Measuring instruments; Samples; Soil tests; Soils; Strain (Mechanics); Testing equipment; Tests; Triaxial shear tests
- Old TRIS Terms: Resistance; Strains
- ITRD Terms: 6155: Apparatus (measuring); 5595: Deformation; 6136: Measurement; 5483: Movement; 6251: Sample (mater); 4156: Soil; 6255: Test; 5566: Triaxial
- Subject Areas: Geotechnology; Highways;
Filing Info
- Accession Number: 00367529
- Record Type: Publication
- Source Agency: Transport Research Laboratory
- Files: ITRD, TRIS
- Created Date: Nov 30 1982 12:00AM