Current Estimation Method at the Time of a Contact Wire Breakage during Standstill below Insulated Overlap Based on Contact Wire Necking Length
One of the critical points in the DC feeding system is the insulated overlap. In the insulated overlap, the contact wire breakage accident during standstill sometimes occurred. It is caused by joule heat due to the current flowing between the contact wire and the contact strip, through the arc due to poor contact condition. To understand the phenomenon of this kind of accident and to take countermeasures against it, it is important to evaluate the current that flows through breakage point. However, since the current is affected by the other train load current, it is difficult to estimate it based on the recorded data of the substation.Once the contact wire is softened, its mechanical strength decreases resulting in breakage due to tension force. The authors conducted wire break tests focusing on the arc. As a result, it has been found that the necking of the contact wire at the point of the breakage caused by the arc depends on the arc current and tension of the contact wire. In this study, the relationship between the arc current, the tension of the contact wire, and the necking length of the contact wire was investigated through the tests conducted under the condition where the arc current was set from about 30 A to 300 A under the tension of 9.8 kN or 19.6 kN. Then the authors proposed a method of estimating the current of the contact wire at the time of its breakage accident during standstill in the insulated overlap section based on the necking length of the contact wire.
- Record URL:
- Record URL:
-
- Record URL:
-
Availability:
- Find a library where document is available. Order URL: http://worldcat.org/issn/00339008
-
Authors:
- WADA, Shogo
- ITO, Kazuhiko
- HAYASAKA, Takamasa
- Publication Date: 2020
Language
- English
- Japanese
Media Info
- Media Type: Digital/other
- Features: Figures; Photos; References;
- Pagination: pp 34-39
-
Serial:
- Quarterly Report of RTRI
- Volume: 61
- Issue Number: 1
- Publisher: Railway Technical Research Institute
- ISSN: 0033-9008
- EISSN: 1880-1765
- Serial URL: https://www.jstage.jst.go.jp/browse/rtriqr/-char/en
-
Publication flags:
Open Access (libre)
Subject/Index Terms
- TRT Terms: Contact wire; Direct current; Electric railroads; Estimating; Fracture mechanics; Railroad trains
- Subject Areas: Energy; Maintenance and Preservation; Railroads; Vehicles and Equipment;
Filing Info
- Accession Number: 01738040
- Record Type: Publication
- Source Agency: Japan Science and Technology Agency (JST)
- Files: TRIS, JSTAGE
- Created Date: Apr 27 2020 9:11AM