Fatal Penetrating Neck Injury Due to Defective Airbag Inflator
The authors present a case of a fatal motor vehicle collision of a 22-year-old car driver, who died at the scene after losing control of his car, and subsequently collided with a tree by the roadside. The subsequent autopsy revealed penetrating injuries on the neck, severing the larynx, carotid artery, jugular vein and fracturing the cervical vertebrae. Internal examination showed the offending material to be a semi-cylindrical metal fragment, which had lodged within the paravertebral muscle. Examination of the car with the authorities found that the metal fragment originated from a defective airbag booster cannister, which shattered upon deployment.