DURABILITY OF D-SIZE SEALED NICKEL-CADMIUM CELLS
D-size sealed nickel-cadmium cells for use in portable electric lamps were investigated on their life performances. The test uas carried out by varying the depth of discharge in three steps for 63 cells taken out of thousands of the cells. The durability of the tested cells was more than 5,600 cycles when the depth of discharge was one-third of the nominal capacity. But it varied from 2,400 to more than 3,200 cycles when the depth of discharge was two-thirds. On the other hand, it was much shorter than this at the cycling of charge and full-discharge. The reason why the test cells deteriorated with repeated cycles of charge and discharge will be attributed to the lowering in their retention of charge.
-
Availability:
- Find a library where document is available. Order URL: http://worldcat.org/oclc/3127232
-
Corporate Authors:
JAPANESE NATIONAL RAILWAYS
TOKYO, Japan -
Authors:
- Sugita, K
- Publication Date: 1973-9
Media Info
- Features: Figures; Tables;
- Pagination: p. 165-167
-
Serial:
- Railway Technical Research Institute, Quarterly Reports
- Volume: 14
- Issue Number: 3
- Publisher: Railway Technical Research Institute/Tetsudo Gijutsu Kenkyujo
- ISSN: 0033-9008
- Serial URL: http://www.rtri.or.jp/eng/
Subject/Index Terms
- TRT Terms: Communications; Electric batteries; Nickel cadmium batteries; Signaling
- Subject Areas: Energy; Railroads;
Filing Info
- Accession Number: 00050875
- Record Type: Publication
- Source Agency: Railway Technical Research Institute
- Report/Paper Numbers: Quart Rpt
- Files: TRIS
- Created Date: Feb 15 1974 12:00AM