Performance analysis of Tohoku-Shinkansen viaducts affected by the 2011 Great East Japan earthquake
Tohoku-Shinkansen viaducts in eastern Japan were designed in accordance with specifications published in the 1970s. They have less shear reinforcement than required by current design specifications. Consequently, the No. 5 Inohana viaducts of Tohoku-Shinkansen failed in shear during the 2003 Sanriku-Minami earthquake. The viaducts were retrofitted by means of steel jacketing so that they had sufficient shear capacity. The retrofitted columns of the viaducts performed well during the 2011 Great East Japan earthquake. However, there is a lack of understanding of the impact of these retrofitting interventions on the vulnerability of the viaduct. It is important to recognise the relationship between the damage to the Shinkansen viaduct with retrofitted reinforced concrete columns and the ground motion intensity. After a brief review of the history of the performance of Shinkansen viaducts to several earthquakes prior to the 2011 Great East Japan earthquake, this paper presents fragility curves of the retrofitted and non-retrofitted Tohoku-Shinkansen viaducts based on nonlinear dynamic analyses and Monte Carlo simulation. It was found that the median of the fragility curve associated with the ultimate limit state for retrofitted viaduct is at least five times larger than that for as-built viaduct.
- Record URL:
-
Availability:
- Find a library where document is available. Order URL: http://worldcat.org/issn/15732479
-
Supplemental Notes:
- Abstract reprinted with permission of Taylor & Francis.
-
Authors:
- Akiyama, Mitsuyoshi
- Frangopol, Dan M
- Mizuno, Keita
- Publication Date: 2014-9
Language
- English
Media Info
- Media Type: Web
- Features: Figures; References; Tables;
- Pagination: pp 1228-1247
-
Serial:
- Structure and Infrastructure Engineering
- Volume: 10
- Issue Number: 9
- Publisher: Taylor & Francis
- ISSN: 1573-2479
- EISSN: 1744-8980
- Serial URL: http://www.tandfonline.com/loi/nsie20
Subject/Index Terms
- TRT Terms: Dynamic structural analysis; Earthquake resistant design; Earthquakes; Reliability; Retrofitting; Shear reinforcement; Viaducts
- Identifier Terms: Great East Japan Earthquake, 2011; Tohoku Shinkansen
- Subject Areas: Bridges and other structures; Design; Railroads; I24: Design of Bridges and Retaining Walls;
Filing Info
- Accession Number: 01529267
- Record Type: Publication
- Files: TRIS
- Created Date: Jun 30 2014 9:41AM