SERVICE FAILURES AND THEIR IMPLICATIONS FOR BRITISH RAILWAYS

Failures in welded and bolted track, tram wheels, nozzle rings, frames and similar components, due to fatigue cracking, thermal cracking, spalling, voids, fracture, and similar mechanisms are discussed. Photomicrographs are used to evaluate failure modes.

  • Corporate Authors:

    Sheffield University Metallurgical Society

    Sheffield 510-2TN
    Yorkshire,   England 
  • Authors:
    • Waldron, GWJ
    • Wise, S
  • Publication Date: 1972

Media Info

Subject/Index Terms

Filing Info

  • Accession Number: 00044503
  • Record Type: Publication
  • Source Agency: Engineering Index
  • Files: TRIS