PHYSIOLOGICAL APPRAISAL OF THE REVEALING POWER OF STREET LIGHTING INSTALLATIONS FOR LARGE COMPOSITE OBJECTS

DUNBAR'S VALUES OF THE LUMINANCE DIFFERENCE THRESHOLD UNDER STREET LIGHTING CONDITIONS ARE CONFIRMED BY NEW MEASUREMENTS SHOWING THE INFLUENCE OF MOTION OF THE OBJECT, EXPOSURE TIME AND PROBABILITY OF RECOGNITION. THE VISIBILITY OF THE STANDARD TEST OBJECT UNDER DYNAMIC CONDITIONS AND UNDER THE INFLUENCE OF DISABILITY GLARE IS DERIVED, LEADING TO THE REVEALING POWER. THERE IS EVIDENCE THAT THE LIMITATION OF DISABILITY GLARE IS RELATED TO THE VALUE OF REVEALING POWER. THE STATISTICAL TREATMENT OF THE REVEALING POWER OF LARGE COMPOSITE OBJECTS, SUCH AS PEDESTRIANS, LEADS TO REASONABLE VALUES OF REVEALING POWER. THIS SINGLE FIGURE SHOULD BE USED AS A FIGURE OF MERIT FOR APPRAISING THE QUALITY OF A STREET LIGHTING INSTALLATION, TAKING INTO ACCOUNT THE INDIVIDUAL PHYSIOLOGICAL ASPECTS OF AVERAGE LUMINANCE LEVEL, LUMINANCE DISTRIBUTION, DISABILITY GLARE AND CONTRAST RENDERING. /AUTHOR/

  • Availability:
  • Supplemental Notes:
    • Vol 3, No 4, PP 268-273
  • Authors:
    • Hentschel, H J
  • Publication Date: 1971

Media Info

Subject/Index Terms

Filing Info

  • Accession Number: 00221640
  • Record Type: Publication
  • Files: TRIS
  • Created Date: Apr 10 1972 12:00AM