Standard and Application by Using Non-Contact Magnetic Tomography Method for Pipeline Technical Conditions Diagnosis

Non-contact Magnetic Tomography Method(MTM) carries out in semiautomatic mode the non-destructive testing of pipeline metal technical condition and its insulating coating condition in 100% volume. The danger of faulty sections is evaluated depending on the degree of stress concentration in anomaly area according to RD 102-008-2009 “Directions for diagnostics of pipeline technical condition by non-contact magneto metric method”. Combining the Xinjiang oilfield, pipeline company field application, there is a detail analysis about the standard contents involving defect location, defect recognition, safe working pressure, dangerous degree, repair advice, test process, data analysis, results evaluation, and on-site check program and so on. And the MTM technical advantages and characteristics are clarified, for further promotion application provides conditions.

Language

  • English

Media Info

  • Media Type: Digital/other
  • Features: References;
  • Pagination: pp 1049-1058
  • Monograph Title: ICPTT 2011: Sustainable Solutions For Water, Sewer, Gas, And Oil Pipelines

Subject/Index Terms

Filing Info

  • Accession Number: 01469760
  • Record Type: Publication
  • ISBN: 9780784412022
  • Files: TRIS, ASCE
  • Created Date: Jan 17 2013 1:48PM