HOT WATER-CIRCULATING IN PLASTIC PIPING SYSTEMS RENDERS POSSIBLE THE ECONOMICAL HEATING OF ROAD SURFACES (GERMAN)

IN ODENSE (DENMARK) THE CARRIAGEWAY OF A BRIDGE APPROACH IS BEING HEATED BY DISTRICT HEATING RETURN WATER OF 40-50 DEGREES C. THE SERVICE SYSTEM CONSISTS OF HARD PVC PIPES (2,396M WITH 24-90 MM), WHICH ARE SET INTO SPECIALLY SHAPED 6-CORNERED CONCRETE MOULDS AND COVERED WITH 5 CM OF GUSSASPHALT. THE TOTAL CONSTRUCTION COSTS AMOUNTED TO DM 47,500 (INCLUSIVE OF SERVICING SPACE AND PIPING FROM THE DISTRICT HEATING SYSTEM), AND THE OPERATION COSTS WERE DM 2,370 FOR 1963/4 AND DM 1,830 FOR 1964/5. /FG/RRL/

  • Availability:
  • Supplemental Notes:
    • Vol 20, No 2, PP 93-100, 8 PHOT, 13 REF
  • Authors:
    • Honore, R
  • Publication Date: 1966

Media Info

Subject/Index Terms

Filing Info

  • Accession Number: 00218320
  • Record Type: Publication
  • Source Agency: Road Research Laboratory /UK
  • Files: TRIS
  • Created Date: Sep 8 1994 12:00AM