QUANTITATIVE DETERMINATION OF UNCOMBINED MAGNESIUM OXIDE IN PORTLAND CEMENT CLINKER BY X-RAY DIFFRACTOMETRY

A QUANTITATIVE X-RAY DIFFRACTOMETRIC METHOD USING CORUNDUM AS AN EXTERNAL STANDARD HAS BEEN DEVELOPED FOR ESTIMATING UNCOMBINED MAGNESIUM OXIDE IN HIGH-MAGNESIA CEMENT CLINKERS. FOR THESE CLINKERS, SEPARATION OF THE SILICATE PHASES BY SELECTIVE HYDROLYSIS IS NOT NECESSARY. THE X-RAY METHOD HAS PROVIDED RESULTS REPRODUCIBLE TO PLUS OR MINUS 0.5% AND IT COMPARES FAVORABLY WITH CHEMICAL METHODS. THE NON- DESTRUCTIVE NATURE OF THE TEST AND ITS RAPIDITY ARE THE MAIN ADVANTAGES. /AUTHOR/

  • Supplemental Notes:
    • Vol 18, No 10, PP 297-300
  • Authors:
    • Rehsi, S S
    • Majumpar, A J
  • Publication Date: 1968-10

Media Info

Subject/Index Terms

Filing Info

  • Accession Number: 00216759
  • Record Type: Publication
  • Files: TRIS
  • Created Date: Mar 24 1994 12:00AM