COMPARATIVE STUDY OF BENT-UP BARS WITH OTHER FORMS OF SECONDARY REINFORCEMENT IN BEAMS

ALTHOUGH CONSIDERABLE RESEARCH HAS BEEN DEVOTED TO THE EFFECTS OF STIRRUPS AS SHEAR REINFORCEMENT, BENT-UP BARS, WHICH HAVE BEEN USED FOR MANY YEARS AND ARE INCLUDED IN THE RECOMMENDATION OF ALL CODES OF PRACTICE, HAVE RECEIVED LITTLE SYSTEMATIC STUDY. THIS PAPER PRESENTS A DIRECT COMPARISON OF THREE FORMS OF WEB REINFORCEMENT, VERTICAL AND INCLINED STIRRUPS, AND BENT-UP BARS, AND IT IS FOUND THAT THE WEB REINFORCEMENT RATIO PROVIDES A SATISFACTORY BASIS FOR THE EVALUATION OF THE RELATIVE EFFICIENCY OF THESE TYPES. /ACIJP/

  • Supplemental Notes:
    • No 1, Proc VOL 68, PP 32-35, 3 FIG, 2 TAB, 2 REF
  • Authors:
    • Leksukhum, K
    • SMITH, R B
  • Publication Date: 1971-1