CORROSION AND CORROSION PROTECTION OF TENDONS IN PRESTRESSED CONCRETE BRIDGES
THE RESULTS OF AN EXTENSIVE STATE-OF-THE-ART SURVEY ARE REPORTED. ALTHOUGH THE CORROSION OF PRESTRESSING STEEL IS NOT A COMMON PROBLEM, IT HAS OCCASIONALLY CAUSED SERIOUS DAMAGES AND FAILURES. CORROSION OF TENDONS IS CAUSED MOSTLY BY IMPROPER CONSTRUCTION TECHNIQUES INCLUDING HANDLING, STORAGE AND SHIPPING, AND TO A LESSER DEGREE, BY IMPROPER DESIGN. HIGH QUALITY, DENSE, AND IMPERVIOUS CONCRETE OR GROUT CAN FURNISH PERMANENT CORROSION PROTECTION IN MOST ENVIRONMENTS TO WHICH A HIGHWAY BRIDGE IS EXPOSED, PROVIDED THAT CERTAIN REQUIREMENTS ARE SATISFIED. RECOMMENDED CORROSION PREVENTING MEASURES OF A CIVIL ENGINEERING CHARACTER ARE DISCUSSED IN DETAIL. /AUTHOR/
-
Supplemental Notes:
- Vol 69, No 1, PP 42-59, 100 REF
-
Authors:
- Szilard, R
- Publication Date: 1969-1
Media Info
Subject/Index Terms
- TRT Terms: Concrete; Concrete bridges; Construction management; Corrosion; Corrosion protection; Grout; Handling and storage; Handling characteristics; Impervious materials; Prestressed concrete; Shipping; State of the art studies; Storage facilities; Tendons
- Uncontrolled Terms: Handling
- Subject Areas: Bridges and other structures; Construction; Freight Transportation; Highways; Marine Transportation; Terminals and Facilities;
Filing Info
- Accession Number: 00208939
- Record Type: Publication
- Files: TRIS
- Created Date: Aug 4 1994 12:00AM