CULVERT INLET FAILURES - A CASE HISTORY

BENT-UP ENDS HAVE BEEN EXPERIENCED ON THREE LARGE STRUCTURAL PLATE CULVERTS INSTALLED WITH THE UPSTREAM ENDS SQUARE AND PROJECTING TO THE FILL TOE. INSTALLATIONS AND FAILURES ARE DESCRIBED AND ONE EXPLANATION OF THE CAUSE IS PRESENTED. /AUTHOR/

  • Record URL:
  • Supplemental Notes:
    • No 286, pp 13-21, 7 FIG, 1 TAB Distribution, posting, or copying of this PDF is strictly prohibited without written permission of the Transportation Research Board of the National Academy of Sciences. Unless otherwise indicated, all materials in this PDF are copyrighted by the National Academy of Sciences. Copyright © National Academy of Sciences. All rights reserved