GENERALIZED DISCHARGE RELATIONS FOR CUTTHROAT FLUMES
A GROUP OF CUTTHROAT FLUMES WERE RATED UNDER BOTH FREE FLOW AND SUBMERGED FLOW CONDITIONS. GENERALIZED DISCHARGE RATING CURVES CAN BE DEVELOPED DUE TO THE SIMPLICITY OF THE STRUCTURE AND THE GEOMETRIC SIMILARITY BETWEEN FLUME SIZES. TWELVE FLUMES WERE USED IN THIS STUDY, INCLUDING THREE FLUME LENGTHS OF 1.5 FT (0.45M), 3 FT (0.90 M), AND 4.5 FT (1.35 M), AND 4.5 FT (1.35 M), WITH FOUR DIFFERENT THROAT WIDTHS FOR EACH LENGTH. IN CUTTHROAT FLUME STUDIES, WHEREIN A FLUME LENGTH OF 9 FT (2.7 M), AND THROAT WIDTHS VARYING FROM 1 FT (0.3 M) TO 6 FT (1.8 M), WERE STUDIED.
-
Availability:
- Find a library where document is available. Order URL: http://worldcat.org/issn/07339437
-
Supplemental Notes:
- 2 APP
-
Authors:
- Skogerboe, G V
- Bennett, R S
- Walker, W R
- Publication Date: 1972-12
Media Info
- Features: Figures; References; Tables;
- Pagination: p. 569-83
-
Serial:
- Journal of Irrigation and Drainage Engineering
- Volume: 98
- Issue Number: ir 4
- Publisher: American Society of Civil Engineers
- ISSN: 0733-9437
- Serial URL: https://ascelibrary.org/journal/jidedh
Subject/Index Terms
- TRT Terms: Channel flow; Drainage; Flow measurement; Flumes; Hydraulic structures; Irrigation; Measuring instruments
- Uncontrolled Terms: Open channel flow
- Subject Areas: Highways; Hydraulics and Hydrology;
Filing Info
- Accession Number: 00204488
- Record Type: Publication
- Files: TRIS
- Created Date: May 7 1973 12:00AM