TEST OF UPPER ANCHORAGE OF NO. 14S COLUMN BARS IN PYLON DESIGN
A TEST RUN ON A FULL SIZE MODEL REPRESENTING A ONE-FOOT SLICE THROUGH THE UPPER PART OF A PYLON SHOWED THAT NO. 14S COLUMN BARS OF A432 GRADE STEEL COULD BE ADEQUATELY ANCHORED IN 4200 PSI CONCRETE FOR THEIR FULL YIELD STRENGTH IN TENSION PRODUCED BY UNBALANCED LIVE LOAD, EVEN WITHOUT EXTENDING THEM THROUGH THE TOP BEAM TENSILE REINFORCING STEEL. THE FAILURE WAS IN FLEXURE (PLUS DIRECT STRESS) IN A MANNER GIVING BOTH WARNING AND TOUGHNESS. /AUTHOR/
-
Supplemental Notes:
- Rept 113-i, 23 PP, 15 FIG
-
Corporate Authors:
University of Texas, Austin
Cockrell Hall
Austin, TX United States 78712 -
Authors:
- Rajagopalan, K S
- Ferguson, P M
- Publication Date: 1968-8
Subject/Index Terms
- TRT Terms: Anchorages; Bridge towers; Columns; Failure; Flexure; Live loads; Reinforcing steel
- Uncontrolled Terms: Model tests
- Subject Areas: Bridges and other structures; Highways;
Filing Info
- Accession Number: 00208969
- Record Type: Publication
- Files: TRIS
- Created Date: Jun 2 1994 12:00AM