GRANULOMETRIE DES ELEMENTS FINS PAR DIFFRACTION LASER - PRESENTATION ET EVALUATION DE LA METHODE

LA PREMIERE PARTIE S'ATTACHE A DEFINIR LES CARACTERISTIQUES DU GRANULOMETRE (REPRODUCTIBILITE, CORRESPONDANCE ENTRE FOCALES, ETC) ET SES CONDITIONS D'UTILISATION. DANS LA SECONDE PARTIE, ON A COMPARE SUR DES MATERIAUX CALIBRES (FINES ET SABLES) LES RESULTATS OBTENUS AU MICROGRANULOMETRE A LASER ET PAR D'AUTRES TECHNIQUES MICROGRANULOMETRIQUES : SEDIGRAPHE, MICROSCOPE ELECTRONIQUE A BALAYAGE (MEB). CES ESSAIS ONT NOTAMMENT PERMIS DE CONSTATER DANS UN PREMIER TEMPS QUE LES COUPURES SUPERIEURES REALISEES A L'AIDE DE TAMIS NE CORRESPONDAIENT PAS AU DIAMETRE NOMINAL DE CES TAMIS (OBSERVATIONS AU LASER, VERIFIEES AU MEB). TOUTES LES TECHNIQUES QUI UTILISENT UNE COUPURE PREALABLE (PIPETTE, SEDIGRAPHE) SONT DONC ENTACHEES D'ERREURS POUR LES GROSSES PARTICULES. PAR AILLEURS, L'OBSERVATION DE MATERIAUX CONSIDERES COMME ETANT TRES FINS AU SEDIGRAPHE A MONTRE AU LASER ET AU MEB QU'IL S'AGISSAIT EN FAIT DE MATERIAUX BEAUCOUP PLUS GROSSIERS QUE PREVU. IL SERA DIFFICILE POUR UNE NOUVELLE TECHNIQUE COMME LE LASER DE S'IMPOSER, BIEN QU'IL S'AGISSE D'UNE METHODE TRES RAPIDE (50 ANALYSES/JOUR), FIABLE, REPRODUCTIBLE ET SURTOUT QUI DONNE UNE INFORMATION GRANULOMETRIQUE TRES PROCHE DE LA REALITE, CONTRAIREMENT AUX METHODES BASEES SUR LA SEDIMENTATION. (A).

Language

  • French

Media Info

Subject/Index Terms

Filing Info

  • Accession Number: 01266864
  • Record Type: Publication
  • Source Agency: Institut Francais des Sciences et Technologies des Transports, de l'Aménagement et des Réseaux (IFSTTAR)
  • Files: ITRD
  • Created Date: Nov 20 2010 1:09PM