PROBLEMS IN DETERMINING VISCOSITY OF ASPHALTS AT LOW TEMPERATURES WITH SHELL SLIDING PLATE MICROVISCOMETER
A SHELL SLIDING PLATE MICROVISCOMETER WITH IMPROVED STEEL PLATES WAS USED FOR LOW-TEMPERATURE TESTING OF ASPHALT BUT WAS FOUND TO BE INADEQUATE FOR THE STRESSES IMPOSED. THERE IS NEED FOR LOW-TEMPERATURE VISCOSITY VALUES TO ESTABLISH CRACKING OF ASPHALT CONCRETE PAVEMENTS. MANUFACTURERS SHOULD REDESIGN A MICROVISCOMETER TO WITHSTAND THE STRESSES IMPOSED BY LOW-TEMPERATURE TESTING. /AUTHOR/
-
Supplemental Notes:
- ASTM STP 532
-
Authors:
- Busby, E O
- Rader, L F
- Publication Date: 1973-6
Media Info
- Features: Tables;
- Pagination: p. 28-30
-
Serial:
- ASTM Special Technical Publications
- Publisher: American Society for Testing and Materials (ASTM)
Subject/Index Terms
- TRT Terms: Asphalt concrete; Asphalt pavements; Asphalt tests; Fracture mechanics; Low temperature; Microanalysis; Micrometers; Stresses; Viscometers; Viscosity
- Subject Areas: Highways; Materials;
Filing Info
- Accession Number: 00211835
- Record Type: Publication
- Files: TRIS
- Created Date: Apr 27 1974 12:00AM