PROBLEMS IN DETERMINING VISCOSITY OF ASPHALTS AT LOW TEMPERATURES WITH SHELL SLIDING PLATE MICROVISCOMETER

A SHELL SLIDING PLATE MICROVISCOMETER WITH IMPROVED STEEL PLATES WAS USED FOR LOW-TEMPERATURE TESTING OF ASPHALT BUT WAS FOUND TO BE INADEQUATE FOR THE STRESSES IMPOSED. THERE IS NEED FOR LOW-TEMPERATURE VISCOSITY VALUES TO ESTABLISH CRACKING OF ASPHALT CONCRETE PAVEMENTS. MANUFACTURERS SHOULD REDESIGN A MICROVISCOMETER TO WITHSTAND THE STRESSES IMPOSED BY LOW-TEMPERATURE TESTING. /AUTHOR/

  • Supplemental Notes:
    • ASTM STP 532
  • Authors:
    • Busby, E O
    • Rader, L F
  • Publication Date: 1973-6