EVALUATION OF A NUCLEAR ASPHALT-CONTENT GAUGE

THE TROXLER ASPHALT-CONTENT GAUGE, MODEL 2226, WAS EVALUATED IN THE LABORATORY AND TAKEN INTO THE FIELD WHERE ITS RESULTS WERE COMPARED TO CONVENTIONAL REFLUX VALUES. THE PRECISION AS EVALUATED IN THE LABORATORY WAS FOUND TO BE EXCELLENT, EQUIVALENT TO 0.06 PERCENT ASPHALT WITH A 45-SEC COUNT. THE GAUGE HAS TO BE RECALIBRATED FOR DIFFERENT AGGREGATES AND, AS A PRACTICAL MATTER, SHOULD BE RECALIBRATED FOR DIFFERENT MIX TYPES. SAMPLE PREPARATION IS IMPORTANT, AND THE SAMPLES SHOULD BE AS UNIFORM AS POSSIBLE. THE ACCURACY APPEARS TO BE AS GOOD AS THAT OF THE REFLUX EXTRACTOR.

  • Record URL:
  • Availability:
  • Supplemental Notes:
    • Sponsored by Committee on Nuclear Principles and Applications. Distribution, posting, or copying of this PDF is strictly prohibited without written permission of the Transportation Research Board of the National Academy of Sciences. Unless otherwise indicated, all materials in this PDF are copyrighted by the National Academy of Sciences. Copyright © National Academy of Sciences. All rights reserved.
  • Authors:
    • Hughes, C S
  • Conference:
  • Publication Date: 1972

Media Info

  • Media Type: Digital/other
  • Features: Figures; References; Tables;
  • Pagination: pp 1-8
  • Monograph Title: Nuclear applications, pipe corrosion and aggregate and glass bead testing
  • Serial:

Subject/Index Terms

Filing Info

  • Accession Number: 00211786
  • Record Type: Publication
  • ISBN: 0309020840
  • Files: TRIS, TRB
  • Created Date: Apr 17 1973 12:00AM